(MS-1900) 2.8 Inch Screen Multi-Parameter Portable Vital Signs Monitor

Product Description



MS-1900 Vital Signs Monitor

Features:
•Suitable for adult, pediatric and neonatal patient
•Built-in memory, store up to 100 hours of tabular of patient SpO2
•High brightness cold cathode fluorescent backlight LCD +LED display
•Advanced digital processing technology providing accurate measurement during low perfusion and movement situation
•Adjustable audible and visual alarms
•Built-in large capacity rechargeable lithium battery

Specifications:
Dimension and Weight
- Dimension: 285mm*230mm*100mm Weight: 1.7kg(excluding accessories)
Power Supply
- Voltage: AC100~240V, 50/60HZ
Display
- LED + LCD LCD Size: 85mm * 30mm
Battery
- Type: Rechargeable lithium battery 3.7V, 2200mAH
- Working time: 8 hours for continuous working
Alarm
- Level: Low, medium and high Indication: Auditory and visual
Operating Environment
- Temperature: 5 ~ 40 ºC
- Humidity: 15% ~ 80% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Transportation and Storage Environment
- Temperature: -20~50 ºC
- Humidity: 10%~90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
- Trend: 100 hours
NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode: 1,2,3,4,5,10,15,30,60,90,120,180,240 min
- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
- Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 235 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 225 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 125 mmHg
- Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection via software & hardware
SpO2 (Digital Technic)
- Measurement Range: 0 ~ 100 % Resolution: 1 %
- Accuracy: ±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
Pulse Rate
- Measuring and Alarm Range: 0~250bpm
- Accuracy: ±1% or ±1 bpm, whichever is greater
- Resolution: 1bpm
Nellcor-SpO2 (Option)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: 70% ~ 100%, ±2 % (adult)
70% ~ 100%, ±3 % (Neonate)
70% ~ 100%, ±2 % (Low Perfusion)
0% ~ 69%, unspecified
Pulse Rate
-Measurement range: 20 ~ 300 bpm Resolution: 1bpm
-Accuracy: ±3 bpm (20 ~ 250 bpm) Unspecified (251~300 bpm)

PM500-30 Multi-parameter Patient Monitor

MS-8000M Modular Multi-Parameter Patient Monitor

MS-8200 Multi-Parameter Patient Monitor

MS-8500B Multi-Parameter Patient Monitor 15.6Inches

MS-PM400 Handheld Vital Sign Monitor