(MS-DR6800) Digital High Frequency X Ray Radiography X Ray Machine

Product Description



MS-DR6800 Digital HF X-Ray System

Features:

The floating table with bucky stand can meet the photographic requirements of different standing and lying positions. The bed floating and electromagnetic lock design makes it convenient for the accurate position of the lying patient, operation is much more convenient and flexible.

The world leading Toshiba 14" *17" digital flat Panel detector can help you get the high-definition images.

The leading domestic high power compact high frequency X-ray generator and high frequency power inverter makes the machine much more compact and more convenient without the extra high-voltage generator and cable.

The application of the KV and MA digital closed-loop control technology and the real time control of the microprocessor ensure the accuracy and repeatability of the dose.

The multiple automatic protection features and fault tips ensure safety during the operation process.

Technical Parameters:

Power Supply:

Voltage:220V;Frequency: 50Hz

Capacity:≥40kVA

internal resistor:≤0.15Ω

Generator:

Power Output:32KW

Inverter Frequency:30 KHz

Tube Voltage:40kV-150kV

Tube Current:10mA-320mA

Exposure time:1.0ms-6300ms

Digital Controlled X-ray Tube:

Tube Focus:Large Focus/Small Focus:1.2mm /0.6mm

Input Power:Big focus 40kW/Small Focus 20kW

Thermal Capacity:110KJ

Rotary anode Speed:2800rpm

Radiography Table:

Table longitudinal movement:≥900mm

Table transverse movement:≥220mm

Pillar movement along table:≥1300mm

Detecting holder movement:≥500mm

Tube assembly up-down movement:500mm~1280mm

Collimator:Manual Multi-leaf

Table use fixed grid :Grid density 103L/INCH, grid 10:1/SID: 120cm/fixed model: 15″×18″

Bucky Stand:

Radio-graphic device movement along pillar:≥1300mm

Cassette SID: 450 ~1780mm

Fixed grid: Grid density 103L/INCH, grid 10:1/SID 180cm/Size: 15″×18″

Flat Panel Detector:

Vision size:358mm(H)×430 mm(V)

Pixel Matrix:2560(H)×3072(V)

Pixel gap:139 μm

Imaging time:less than 10s

Limiting resolution:3.5 lp/mm typ

A / D transform:14 bit

Energy range:40 - 150 kVp

Biggest input dose(low transmission gain):4 mR / frame

Date out:A 16-bit digital output Ethernet(1000BASE - T)

Command control:Ethernet(1000BASE - T)

Power input:DC 24V/4.8A