MS-VLS400 Flexible Video Laryngoscope

Product Description

MS-VLS400 Flexible Video Laryngoscope

Application:
Anesthesia department, ICU, NICU, emergency department, respiratory department and so on.
Features:
1. Monitor front and rear, left and right multi-angle rotation observation.
2. Flexible intubation bending flexible, can be through the mouth or nasal cannula.

3. According to customer needs with a variety of laryngoscopes, tracheal tubes, trolleys and other tools, the establishment of anesthesia intubation workstation.

Specifaction:

Model Item: MS-VLS400

Visual Field

90°

Visual direction

observe depth

3-100mm

Intubation Tube out diameter

2.8mm,3.8mm

working length

300mm-600mm

curved angle

upward≥180° downward≥ 130°

resolution ratio

960*480

pixel

600,000 pixels

LCD diplay size

3.5” TFT LCD

display Revolve angle

Up to down 0-180°,left to right 0-330°

power lithium battery /capacity

3.7V polymer battery (don’t need to remove),1850mA

charge time

> 600 times

data save method

16G memory card,stored> 10,000pcs photos,video≥4.5 hours.

Charger input

AC 100-240V, 50-60Hz

After-sales service

2years


Product Configuration:

ITEM

QTY

MATERIAL

3.5inch display

1set

aluminum magnesium alloy

operative section

1pc

aluminum magnesium alloy

Recharger battery

1pc

PC

laryngoscope

1set

304 medical stainless steel

Leak detector

1pc

plastic

Sealing Ring

2pcs

rubber

SD save card

1pc

plastic

Leak cover

1pc

aluminum

 

Optional : endoscopy trolley, disinfection tank, biopsy forceps, laveur ,Disinfection gun,bronchoscope locker.......

 

 

Operation procedure:

1. Firstly, lubricate the endotracheal tube and endoscopic insertion tube.

2. Insert the endotracheal tube and fix the hose to the endotracheal tube connector.

3. Open the endoscope and check the bending of the end.

4. Insert the endoscope into the patient's mouth with mandibular thrust.

5. Insert it into the end of the screen and adjust it downward in time to keep a clear view of the screen.

6. Locate the epiglottis area, then adjust the control knob to properly bend the end, and gently rotate the control handle to slide the end through the affected epiglottis area.

Find the vocal cords.

8. Hold the endoscope and push the trachea catheter to rotate quickly into the patient.

9. Quickly draw out the endoscope and insert the tube and observe the display screen to check the correct position of the endotracheal tube.

10. Quickly connect the trachea catheter to the ventilator.


MS-VLA300 Video Laryngoscope

MS-VLA500 Video Laryngoscope

MS-VLA500D Video Laryngoscope

MS-VLS600 Flexible Video Laryngoscope