chanpin
You are here: Home / Products / Monitoring / ECG / (MS-1203H) Three Channel LCD Electrocardiograph EKG ECG

loading

Share to:
sharethis sharing button

(MS-1203H) Three Channel LCD Electrocardiograph EKG ECG

Quantity:
  • Shanghai, China

  • 1000PCS/Year

  • L/C, T/T, Western Union, Paypal, Money Gram

  • MS-1203H

  • customized

  • 1 Piece in Carton

  • 390*310*640mm

  • China

  • 9018193010

  • Imaging Diagnostic Equipment

  • Digital EEG/ECG/EKG/EMG/VCG

  • CE, FDA, EEC, MSDS, ISO13485

  • Middle-aged and Old

  • 4.5 Kg

  • 2.5 Kg

(MS-1203H) Three Channel LCD Electrocardiograph EKG ECG

MS-1203H Three Channel ECG


1) Features :
1 Anti-baseline drift and AC, EMG interference
2 Automatically adjust baseline, optimize print position
3 Working modes: Manual, Automatic, Arrhythmia Analysis, Storage (300 cases)
4 High resolution hot spot array printing, electrocardiogram lifelike, exquisite
5 Precise ECG auto-interpretation program
6 With advanced pacemaker detection
7 Touch button with touch screen, easy to operate
8 AC-DC dual purpose , long working hours
9 480x272 graphic 4.3 inch color LCD to simultaneously display ECG information
10 Probe exfoliation alarm function and electrode position display
11 12 seconds waveform freeze, print preview display function
12 Flexible output print format: Standard 3-channel, rhythmic lead and manual 3-channe
printing format
13 Adapt to 110-230V,50/60Hz power supply. Built-in rechargeable Ni-MH battery

2) Technical Specification :

Lead Standard 12 leads Time constant ≥3.2s
Lead acquisition 12bit/16 bit/ 24bit (synchronously 12 leads) Frequency response 0.05~150Hz(-3db)
Work mode Man / Auto/Analysis/Storage Noise level <15μVp-p
HR Technique Peak-peak detection HR Recognition HR Range: 30 BPM ~ 300BPM
Accuracy: ±1 BPM
Anti-baseline drift Automatic Working mode Manual, Automatic, Arrhythmia Analysis, Storage (300 cases)
Filter AC Filter : 50Hz / 60Hz
EMG Filter : 25Hz / 35Hz/Off
Anti-Drift Filter : 0.05/0.15/0.25/0.5Hz /ADP
Lowpass Filter: 150/100/75 Hz
Inter-channel Interference ≤0.5mm
CMRR ≥100dB (with AC FILTER) Sensitivity 2.5,5,10,20 Auto (mm/mV)
Input circuit Floating; Protection circuit against
Defibrillator effect
Recording mode 1ch+, 3ch, 3ch+
Default Man. Mode is 3ch format
Default Auto. Mode is 3ch+ format
Input Impedance ≥50MΩ Paper speed 5,10,25,50mm/s(±3%)
Input circuit current ≤0.05μA Measurement Range ± 5mVpp
Sample Rate Normal: 1000sps/ch, pacemaker: 10,000sps/ch Pacemaker Detection ≥ ± 2mV ; ≥ ±0.1ms
Patient current leakage <10μA Power Supply AC 110-230V(±10%),50/60Hz(±1Hz),60VA
DC Built-in rechargeable battery,12V (1500mAh)
Calibrating voltage 1mV±3% Voltage tolerance ≥±500mV