(MS-300P) Emergency Aed Portable Automatic Cardiac Biphasic External Defibrillator

Quantity:
  • Shanghai, China

  • 100000PCS/Year

  • L/C, T/T, Western Union, Paypal, Money Gram

  • MS-300P

  • Semi Open Suction

  • Portable

  • 1.5 Kg

  • 1.2 Kg

  • customized

  • 1 Piece in Carton

  • 303 x 216 x 89mm

  • China

  • 9018193010

  • Defibrillator

  • External Biphasic Defibrillator

  • CE, ISO13485

  • Adult

  • With LCD Display

  • Oxygen

(MS-300P) Emergency Aed Portable Automatic Cardiac Biphasic External Defibrillator
(MS-300P) Emergency Aed Portable Automatic Cardiac Biphasic External Defibrillator


MS-300P Portable Aed Automatic External Defibrillator

Features:
Color Screen size:3.5"
Automatic Self-testing
Biphasic Energy Output
CPR Metronome
CPR Coaching (Optiona)
Adult and Pediatric Defibrillation
Extensive Voice and sisual promputs

Defibrillator
Category Specification
Output Biphasic Truncated exponential
Energy Sequence(adult ) 150/150/200(Default)
150/200/200
200/200/200
Note: the Energy sequence can be changed using the computer IR port.
Energy Sequence(Pediatric) 50/70/85(Default)
70/70/85
70/85/85
85/85/85
Note: the Energy sequence can be changed using the computer IR port.
Charge Time 10 sec. to 200 J
Analysis Time 9 sec.
The maximum time from the initiation of rhythm analysis to readiness for maximum Energy discharge after 15 shocks. Less than 30 seconds
The maximum time from initially switching power on to readiness for maximum Energy discharge after 15 shocks.. Less than 35seconds
Audible Prompts 19 audible prompts
Visual Prompts LED/LCD
Controls six buttons - On/Off, Shock, and 4 software-configurable buttons
Output Energy Accuracy ±15% into any impedance from 25 to 175Ω
The Maximum Voltage 1800±20V
Output disabled when the PATIENT impedance is outside limits 20Ω to 200Ω
Recovery of the ECG input after defibrillation <10s
the time from switching "ON" until the unit is ready for NORMAL USE, <4s
he time required for the ME EQUIPMENT to warm from the minimum storage temperature between uses (4.2.1) until the ME EQUIPMENT is ready for its INTENDED USE when the ambient temperature is 20 °C >30min
he time required for the ME EQUIPMENT to cool from the maximum storage temperature between uses (4.2.1) until the ME EQUIPMENT is ready for its INTENDED USE when the ambient temperature is 20 °C >1min
Previous: 
Next: 
ABOUT US 
Medical Sources Co.,Ltd.,located in Nanjing & having branch in Hongkong,is a leading professional supplier and exporter for medical equipments in China. For many years, we have been dedicating to provide state-of-the-art products with top-ranking quality to global clients around the world.
CONTACTS US
  • Huaying Building,No.40-1 Beijing East Road,Nanjing,China Zip:210008
  • (+86 25 84697820)
    (+86 139 13039913)
Copyright © 2020 Medical Sources Co.,Ltd.,Technology by www.leadong.com