(MS-380C) First Aid Portable Biophasic Defibrillator Monophasic Aed Defibrillator

MS-380C Biophasic Defibrillator


Physical characteristics:

Main unit: Portable

Dimensions:L320xW205xH410

Weight:9.8kg

Technical specifications


Defibrillator:

(1) Defibrillator type Manual, Synchronized, Asynchronized,

(2) Out put waveform Biphasic technology

(3) Energy accuracy ∠+1%

(4) Energy selection 0,3,5,7,10,20,30,50,100,200,300,360 joule(normal at a resistance of 50)

(5) Charging time Maximum 8 seconds to 360 Joules

(6) Standard Adult/Pediatric Paddles Reusable extermal adult paddles(pediatric paddles integrated)


Power requirements

(a) AC Power supply 110V, 60 Hz /220V,50 Hz

(b) Vehicle Voltage DC 12V


Internal Battery Backup

(1) Battery type Rechargeable lithium battery

(2) Charging time Time-Minimum of 4 hours for full charging

(3) Battery charging During AC Power Supply operation of the device.

(4) Charging /Low Battery Indication Red LED

(5) Battery Capacity 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.


Display

-LED Dimensions 7'diagonal {155mm*88mm}

-Type High resolution true-color graphic LED

-Resolution 480X234


ECG

ECG lead: I, II, III, AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protegtion: With stand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation


Respiration

Measurement method: Thoracic impedance


NIBP

Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cufftype: standard Adult; optional Pediatric/Neonatal


Temperature

Measurement range 20~45ºC

Resolution 0.1ºC


Pulse Oximetry(spO2)

Display :spo2 value,pulse histongram,waveform,Pulse

Range: 0~99%for adult,pediatric and neonatal patients

Probe :standard adult finger clip

optional pediatric Y-type clip and neonatal wrap


Pulse range
Pulse range: 0-255bpm


Standard parameter & configuration

ECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR

Optional parameter

Recorder

Previous: 
Next: 
ABOUT US 
Medical Sources Co.,Ltd.,located in Nanjing & having branch in Hongkong,is a leading professional supplier and exporter for medical equipments in China. For many years, we have been dedicating to provide state-of-the-art products with top-ranking quality to global clients around the world.
CONTACTS US
  • Huaying Building,No.40-1 Beijing East Road,Nanjing,China Zip:210008
  • (+86 25 84697820)
    (+86 139 13039913)
Copyright © 2020 Medical Sources Co.,Ltd.,Technology by www.leadong.com