(MS-390D) Portable First Aid Emergency Aed Cardiac Biphasic Automatic External Defibrillator

Quantity:
  • Shanghai, China

  • 10, 000, 000 PCS/Year

  • L/C, T/T, Western Union, Paypal, Money Gram

  • MS-390D

  • Semi Open Suction

  • Portable

  • 1.5 Kg

  • 1.2 Kg

  • customized

  • 1 Piece in Carton

  • 303 x 216 x 89mm

  • China

  • 9018193010

  • Defibrillator

  • External Biphasic Defibrillator

  • CE, ISO13485

  • Adult

  • With LCD Display

  • Oxygen

(MS-390D) Portable First Aid Emergency Aed Cardiac Biphasic Automatic External Defibrillator

(MS-390D) Portable First Aid Emergency Aed Cardiac Biphasic Automatic External Defibrillator
(MS-390D) Portable First Aid Emergency Aed Cardiac Biphasic Automatic External Defibrillator


MS-390D Portable Aed Automatic External Defibrillator

Display:
Screen Type: High-resolution display
Screen Size: 7 inches(17.7cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm on/Off, SpO2, AED functions and Prompts,Alarm Selection and Limits, Delivered Energy.

Defibrillator:
Waveform: Biphasic
Energy Display: Monitor display indicates both selected and delivered energy
Charge Prompt Type: Voice and visual prompts
Electrode Impedance Measurement Range: 0-250 ohms

ECG Monitoring
Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles
Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF,V
ECG size: 0.25,0.5,1,1.5,2,4cm/mV display on monitor.
Heart Rate: 20-300 BPM
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockable rhythm.

Battary
Type: Rechargeable, Ni-MH battary, 12V
Operating Time: For a new, fully charged battary 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring , Additional parameters willl effect operating time with different functions.


SpO2 Module
Measurement Range: 30-100%, ±2% between 80%-90%, others ±5%.
Alarm Range: Users set high limit and low limit.
Alarm Accuracy: ±10% within setting values.
Alarm time Accuracy: less than 12 sec.

Recorder
Paper: 50mm thermal
Speed: 12.5mm/sec, 25mm/sec,50mm/sec,User-selectable 6 second delay.
Printing Method: High-resolution, thermal array print head.
Print-out Moudes: Manual or automatic, user-configurable.
On.Off Control: Front panel and paddle.
Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge

AED Mode
AED function: Auto analyze and charge×3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms: Ventricular fibrillation Ventricular tachycardia, QRS complex wave duration.
Charge Control: Control on device front panel.press key on paddle.

Manual Mode
Energy Selection: Selecable at 2,5,7,10,20,30,50,70,100,150,200,300,360joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave, "SYNC" message displayed on monitor.