MS-8000M
MS
Shanghai, China
10000PCS/Year
L/C, T/T, Western Union
MS-8000M Dodular Patient Monitor
Features
Touch-screen for easy operation
12.1 inch high resolution color TFT display
USB interfaces support easy software upgrade and data transfer
Compatible with Central Monitoring System(CMS)
Three Working Modes:Monitoring,Surgery and Diagnosis.
Simple and friendly operating display interface.
Multi-display modes suitable for different applications:
Standard Interface,Large font,ECG Standard Full Display, OXY,Trend Table,BP Trend.
Built-in high capacity battery up to 3 hours of continuouswork
VGA output for external display
Technique Specification
ECG
Lead Mode:5 Leads (I,II,Ill,AVR,AVL,AVF,V)
Gain:2.5mm/mV,5.0mm/mV,10mm/mV,20mm/mV
Heart Rate:15-300 BPM(Adult); 15-350 BPM(Neonatal)
Resolution:1 BPM
Accuracy:±1%
Sensitivity>200 uV(Peak to peak)
ST measurement range:-2.0~+2.0 mV
Accuracy:-0.8mV~+0.8mV:±0.02mV or ±10%,which is greater
Other Range:unspecified
Sweep speed:12.5 mm/s,25mm/s,50mm/s
Bandwidth:
Diagnostic:0.05~130 Hz
Monitor: 0.5~40 Hz
Surgery:1~20 Hz
SPO2 | Optinal Parameters: |
Measuring Range:0~100% | Dual IBP Module |
Resolution:1% | Etco2 Module |
Accuracy:70%~100% (±2%) | Recorder(Printer) |
Pulse Rate:20-250 BPM | Central monitoring system |
Resolution:1 BPM | Nellcor SpO2; |
Accuracy:±3 BPM | Sun Tech NIBP. |
MS-8000M Dodular Patient Monitor
Features
Touch-screen for easy operation
12.1 inch high resolution color TFT display
USB interfaces support easy software upgrade and data transfer
Compatible with Central Monitoring System(CMS)
Three Working Modes:Monitoring,Surgery and Diagnosis.
Simple and friendly operating display interface.
Multi-display modes suitable for different applications:
Standard Interface,Large font,ECG Standard Full Display, OXY,Trend Table,BP Trend.
Built-in high capacity battery up to 3 hours of continuouswork
VGA output for external display
Technique Specification
ECG
Lead Mode:5 Leads (I,II,Ill,AVR,AVL,AVF,V)
Gain:2.5mm/mV,5.0mm/mV,10mm/mV,20mm/mV
Heart Rate:15-300 BPM(Adult); 15-350 BPM(Neonatal)
Resolution:1 BPM
Accuracy:±1%
Sensitivity>200 uV(Peak to peak)
ST measurement range:-2.0~+2.0 mV
Accuracy:-0.8mV~+0.8mV:±0.02mV or ±10%,which is greater
Other Range:unspecified
Sweep speed:12.5 mm/s,25mm/s,50mm/s
Bandwidth:
Diagnostic:0.05~130 Hz
Monitor: 0.5~40 Hz
Surgery:1~20 Hz
SPO2 | Optinal Parameters: |
Measuring Range:0~100% | Dual IBP Module |
Resolution:1% | Etco2 Module |
Accuracy:70%~100% (±2%) | Recorder(Printer) |
Pulse Rate:20-250 BPM | Central monitoring system |
Resolution:1 BPM | Nellcor SpO2; |
Accuracy:±3 BPM | Sun Tech NIBP. |