MS-M60 Mainstream ETCO2 Sensor

Product Introduction

ETCO2 module is the ideal capnography solution. It is plug-in and play. The sensor features advanced technology for measuring realtime CO2 concentration,  respiration  rate, end-tidal CO2 concentration, inspired CO2 concentration. It resist the vapour better with patented technology, make the measured result more accurate.

Annlication Field

Monitoring the patient’s respiratory status

 

Assisting in determining when to intubate or extubate

 

Verification of ET-tube placement

 

Alarming when accidental extubation occurs

 

Ventilator  disconnect detection

 

Verification of ventilation during transportation

 

 

Technical Specifications

Transducer Type

Side stream CO2 module(MS-S30) and Mainstream CO2 sensor(MS-M60)

Principle of Operation

Non-dispersive infra-Red (NDIR)

 

Initialization Time

Capnogram displayed in less than 6 seconds(side stream) and 2 senconds (mainstream)

 

Reaching full specifications within 2

CO2 Measure Range

0 - 150mmHg

0 - 20.0%

0- 20kPa

 

CO2 Measure Resolution

0.1mmHg(side stream ), 0.01mmHg(mainstream )

 

Co2 Accuracy

0 – 40 mmHg ±2 mmHg

41 – 70  mmHg ±5% of reading

71 – 100 mmHg ±8% of reading

101–150 mmHg ±10% of reading

 

Respiratory Rate

 

 

Range   2 - 150 RPM

 

Accuracy  ±1 breath

 

Calibration

 

No routine user calibration required. An airway adapter zero is required when insert an airway adapter

 

Compensation

 

Barometer Pressure 450 - 850 mmHg.

Operator selectable O2 , N2O, He compensation.

 

Power Consumption

 

5.0 VDC ±5%, power consumption less than 1.3W typical

 

 

Temperature / Humidity

Operating: 0 to 50 ℃, 10 to 90% RH

 

Storage: -40 to 70℃, <90% RH

 

Data Interface

RS232/TTL, 19200 baud rate, standard N-8-1.

Fully compatible with Respironics/Masimo CO2 module’s communication protocol

 

 

 